sales@northernstoragesolutions.co.uk
- Call: 01748 835276
- Drum Storage
- IBC Storage
- Fuel Storage Tanks
- Water Tanks & Storage
- Hazardous Storage
- Spill Control
- Spill Containment
- Garage Equipment
- Equipment & Accessories
- Brands
- Drum Storage
- IBC Storage
- Fuel Storage Tanks
- Water Tanks & Storage
- Hazardous Storage
- Spill Control
- Spill Containment
- Garage Equipment
-
Equipment & Accessories
- Fuel Transfer Pumps
- Diesel Pumps
- Petrol Pumps
- AdBlue Pumps
- Electric Transfer Pumps
- Manual Hand Pumps
- Flow Meters
- Mechanical Fuel Flow Meters
- Digital Fuel Flow Meters
- Fuel Pulse Meters
- Fuel Triggers & Nozzles
- Diesel Nozzles
- Petrol Nozzles
- AdBlue Nozzles
- Automatic Fuel Nozzles
- Manual Fuel Nozzles
- Fuel Hoses & Hose Reels
- Fuel Hoses
- Fuel Hose Reels
- Hose Fittings
- Brands
50000 Litre NTS Containerised Diesel Dispensing Tank

Totally enclosed generator stores have been specifically designed and are capable of housing all makes of generators up to 100KVA. They offer exceptional protection against the elements and theft and offer full protection in the unlikely event of a fuel spillage eliminating the need for additional oil interceptor trays. Large access doors are fitted for easy access for maintenance.
Features -
Front access doors: fitted with two, 5 lever dead locks (keyed alike) & two heavy duty spring bolts.
Louvered air intake: One located each side front side with filter mesh and noise deflector plates.
Louvered air outlet: One located in rear panel with filter mesh.
Exhaust outlet: Three interchangeable, high level above air outlet. One located in air outlet panel with removable cover plate.
Extractor fan: Located in the rear of the unit at a high level, fitted with thermostat.
Lifting points: Four Top lift & four low level strapping and lifting points.
Fork lift points: W250 x H135.
Twist locks plates: Twist locks fitted in base of store for easy transportation.
Earthing boss: 10mm located either side near air intake panel.
Cable outlet: Located either side near air intake panel removable plate for access L240 x H150.
Totally enclosed generator stores have been specifically designed and are capable of housing all makes of generators up to 100KVA. They offer exceptional protection against the elements and theft and offer full protection in the unlikely event of a fuel spillage eliminating the need for additional oil interceptor trays. Large access doors are fitted for easy access for maintenance.
Features -
Front access doors: fitted with two, 5 lever dead locks (keyed alike) & two heavy duty spring bolts.
Louvered air intake: One located each side front side with filter mesh and noise deflector plates.
Louvered air outlet: One located in rear panel with filter mesh.
Exhaust outlet: Three interchangeable, high level above air outlet. One located in air outlet panel with removable cover plate.
Extractor fan: Located in the rear of the unit at a high level, fitted with thermostat.
Lifting points: Four Top lift & four low level strapping and lifting points.
Fork lift points: W250 x H135.
Twist locks plates: Twist locks fitted in base of store for easy transportation.
Earthing boss: 10mm located either side near air intake panel.
Cable outlet: Located either side near air intake panel removable plate for access L240 x H150.
Mild steel rigid bunded container with steel portable bund fully welded with mechanical handling base and top lifting facility. Both the inner and outer tanks are constructed from mild steel plate to BS EN 10025.
The unit is manufactured with an integrally bunded tank with capacity to hold an additional 10% of the total liquid being stored which is then fitted within a steel outer bund providing a secondary bund to the main storage tank. A bulk head is fitted in front of the storage tank to provide an area in which all the tanks control and dispensing equipment is housed. A steel roller shutter door is provided for increased security
These units are built to the same stringent standards as the UN approved Fuel Bank range, and capable of being lifted and transported around site when full.
Compliancy:
BS799 part 5,
Control of pollution (oil storage) (England) regulations 2001
PPG2
PPG26
Mild steel rigid bunded container with steel portable bund fully welded with mechanical handling base and top lifting facility. Both the inner and outer tanks are constructed from mild steel plate to BS EN 10025.
The unit is manufactured with an integrally bunded tank with capacity to hold an additional 10% of the total liquid being stored which is then fitted within a steel outer bund providing a secondary bund to the main storage tank. A bulk head is fitted in front of the storage tank to provide an area in which all the tanks control and dispensing equipment is housed. An aluminium roller shutter door is provided for increased security
These units are built to the same stringent standards as the UN approved Fuel Bank range, and capable of being lifted and transported around site when full.
Compliancy:
BS799 part 5,
Control of pollution (oil storage) (England) regulations 2001
PPG2
PPG26