-
sales@northernstoragesolutions.co.uk
- Call: 01748 835276
- Drum Storage
- IBC Storage
- Fuel Storage Tanks
- Water Tanks & Storage
- Hazardous Storage
- Spill Control
- Spill Containment
- Garage Equipment
- Equipment & Accessories
- Brands
- Drum Storage
- IBC Storage
- Fuel Storage Tanks
- Water Tanks & Storage
- Hazardous Storage
- Spill Control
- Spill Containment
- Garage Equipment
-
Equipment & Accessories
- Fuel Transfer Pumps
- Diesel Pumps
- Petrol Pumps
- AdBlue Pumps
- Electric Transfer Pumps
- Manual Hand Pumps
- Flow Meters
- Mechanical Fuel Flow Meters
- Digital Fuel Flow Meters
- Fuel Pulse Meters
- Fuel Triggers & Nozzles
- Diesel Nozzles
- Petrol Nozzles
- AdBlue Nozzles
- Automatic Fuel Nozzles
- Manual Fuel Nozzles
- Fuel Hoses & Hose Reels
- Fuel Hoses
- Fuel Hose Reels
- Hose Fittings
- Brands
20,000 Litre High Security Containerised Diesel Dispensing Tank
Manufactured in the UK from Mild Steel Plate, this Steel Bunded Heating Oil Tank is suitable for the storage of most fuels and light oils.
Included with this Bunded Oil Tank is -
Float Type Bund Gauge
Hydrostatic Tank Contents Gauge
2" BSP Fill Point with Cap
2" BSP Tank Vent with Cap
1" BSP Top feed
Top Lift points (Lift empty only)
1" BSP Spare socket into bund
Overfill Prevention Valve
10 Year Guarantee
This self bunding, steel oil storage tank is manufactured to comply with all current regulations.
Suitable for above ground instillations at Domestic, Commercial, Agricultural and industrial locations for storage of Paraffin, Kerosene, diesel oils and light lubricant oils.
Both the inner and outer tanks are constructed from mild steel plate to BS EN 10025.The inner tank providing the required storage area, the outer tank forms the required bund, with capacity of 110% of the total liquid being stored.
The tank vent is piped into the bund then to atmosphere further reducing the risk of spills in the event of overfilling the tank. Tanks are fitted with steel base supports to eliminate ground contact with the tank base. The tanks can also be fitted with steel legs to raise of the floor for gravity feed applications
Compliancy: BS799 part 5, Control of pollution (oil storage) (England) Regulations 2001, PPG2, PPG26.
Totally enclosed generator stores have been specifically designed and are capable of housing all makes of generators up to 100KVA. They offer exceptional protection against the elements and theft and offer full protection in the unlikely event of a fuel spillage eliminating the need for additional oil interceptor trays. Large access doors are fitted for easy access for maintenance.
Features -
Front access doors: fitted with two, 5 lever dead locks (keyed alike) & two heavy duty spring bolts.
Louvered air intake: One located each side front side with filter mesh and noise deflector plates.
Louvered air outlet: One located in rear panel with filter mesh.
Exhaust outlet: Three interchangeable, high level above air outlet. One located in air outlet panel with removable cover plate.
Extractor fan: Located in the rear of the unit at a high level, fitted with thermostat.
Lifting points: Four Top lift & four low level strapping and lifting points.
Fork lift points: W250 x H135.
Twist locks plates: Twist locks fitted in base of store for easy transportation.
Earthing boss: 10mm located either side near air intake panel.
Cable outlet: Located either side near air intake panel removable plate for access L240 x H150.
This Generator Store has been specifically designed to house most makes of generators and associated equipment. The units have large doors providing excellent access for installation and maintenance. There is also a personnel door fitted for daily access.
The Gen-Store line are of all steel construction and benefit from a built in spillage retention sump (which eliminates the need for additional interceptor trays). It also has an integrally fitted bulk storage tank which can be permanently piped to the generator. The Gen-Store line have the option to be accoustically lined, this allows none canopied sets to be fitted.
Features -
Full width access doors for easy access, fitted with anti jam door pins, five lever dead locks and a removable anti ram bar.
High level exhaust outlet.
Filtered air intake / outlet.
Nose deflector plates on air intakes.
Light and thermostatically controlled heat extractor fan.
Removable step (for transportation)
Built in Fork lift points
Certified Lifting eyes.
Acoustically insulated to between 70 / 90 dbA @ 1mtr subject to equipment fitted.
Mild steel rigid bunded container with steel portable bund fully welded with mechanical handling base and top lifting facility. Both the inner and outer tanks are constructed from mild steel plate to BS EN 10025.
The unit is manufactured with an integrally bunded tank with capacity to hold an additional 10% of the total liquid being stored which is then fitted within a steel outer bund providing a secondary bund to the main storage tank. A bulk head is fitted in front of the storage tank to provide an area in which all the tanks control and dispensing equipment is housed. A steel roller shutter door is provided for increased security
These units are built to the same stringent standards as the UN approved Fuel Bank range, and capable of being lifted and transported around site when full.
Compliancy:
BS799 part 5,
Control of pollution (oil storage) (England) regulations 2001
PPG2
PPG26